SCI Regeneration MapWhat the world knows about repairing the injured spinal cord

Seven directions of research

Epidural electrical stimulation

A list of codes kept in this browser. No name, no medical answer and no account — nothing personal is stored and nothing is registered.

Relationship graph

Class: Implanted device

What this is

A thin electrode implanted in the back, over the covering of the spinal cord, and a small generator under the skin. The device delivers a weak current to the cord below the injury — not to the tear itself and not to the brain.

What problem it is trying to solve

After an injury some fibres are often intact, but the signal from the brain is no longer strong enough to drive them. This approach tries to make those surviving circuits controllable again — without repairing the fibres that were cut.

How it is supposed to work

The proposed mechanism is that the current does not order a muscle to move: it raises the excitability of the network of neurons inside the cord itself. A weak remaining command from above, together with signals from the limb, then becomes enough for the movement to happen.

Where this is known from: National Institute of Neurological Disorders and Stroke (NIH) · nobody has yet read that source against these sentences

What this acts on

The parts of the body and the phases of an injury this technology is aimed at, in plain words. Each one opens the rest of what is known about it.

Open this plate

The same cross-section with three territories filled in — the dorsal columns behind, the anterolateral tract in front and to the side, the corticospinal tract behind it — and beside it a schematic of brain, brainstem and cord in which each of the three is followed as a line to the height at which it crosses to the other side.
×
Plate 4Atlas of a spinal cord injury4of 19The longtractsThe same cross-section with three territories filled in — the dorsal columns behind, the anterolateral tract in front and to the side, the corticospinal tract behind it — and beside it a schematic of brain, brainstem and cord in which each of the three is followed as a line to the height at which it crosses to the other side.Dorsal columnsDorsal columnsCorticospinal tractCorticospinal tractSpinothalamic tractSpinothalamic tractWhere a pathway crosses — The same cross-section with three territories filled in — the dorsal columns behind, the anterolateral tract in front and to the side, the corticospinal tract behind it — and beside it a schematic of brain, brainstem and cord in which each of the three is followed as a line to the height at which it crosses to the other side.Where a pathway crossesWhere a pathway crossesThe brainstemThe brainstem

What is being changed here, drawn

The long tracts

A descending path from the motor cortex to the motor neurons. It carries voluntary movement and crosses to the other side in the brainstem.

Open this plate · 4 of 19 →

  • Corticospinal tractA descending path from the motor cortex to the motor neurons. It carries voluntary movement and crosses to the other side in the brainstem.
  • Building a circuit around the gapInstead of repairing what is damaged, route around it: strengthen the paths that survived or build a new circuit, electrical stimulation among them. This is where epidural electrical stimulation belongs.

How far this has actually got

No step has been recorded for this approach.

A step is recorded when a study in this corpus moves it. Nothing has, so there is no step to show — which is different from the step being zero.

Claims and their evidence states

Human and preclinical evidence are counted separately and never merged.

Human evidence

Nothing has been recorded here yet.

This map holds only what has been read and checked against a source, and nothing has been recorded for this section. Empty here means exactly that — not zero, and not a fault in the page.

Preclinical evidence

Nothing has been recorded here yet.

This map holds only what has been read and checked against a source, and nothing has been recorded for this section. Empty here means exactly that — not zero, and not a fault in the page.

Studies

No study has been recorded for this technology yet.

This map holds only what has been read and checked against a source, and nothing has been recorded for this section. Empty here means exactly that — not zero, and not a fault in the page.

Limits and known risks

It is surgery: anaesthesia, an implant, a risk of infection, of the device moving or failing, and of a second operation. Settings are tuned individually and slowly. Effects are described in small groups of participants; no work in this corpus shows a lasting result with the device switched off.

Safety signals

No safety signal has been recorded.

This map holds only what has been read and checked against a source, and nothing has been recorded for this section. Empty here means exactly that — not zero, and not a fault in the page.

Who researches this, and where

The sites are those the registry record names itself, word for word. A place that is absent was not published by the registry, and no location here is guessed.

Where this work was done

No place is recorded for the studies behind this technology.

A place is kept only where the source published one in the field its basis names. Some registry records do not publish a facility, and nothing is inferred from an address that was never given.

Laboratory

Nothing has been recorded here yet.

This map holds only what has been read and checked against a source, and nothing has been recorded for this section. Empty here means exactly that — not zero, and not a fault in the page.

Clinical trial

Nothing has been recorded here yet.

This map holds only what has been read and checked against a source, and nothing has been recorded for this section. Empty here means exactly that — not zero, and not a fault in the page.

What is still missing

What is missing: large controlled comparisons, a shared protocol for tuning the device, and follow-up measured in years rather than months.

Completeness of the literature search

Nothing has been recorded here yet.

This map holds only what has been read and checked against a source, and nothing has been recorded for this section. Empty here means exactly that — not zero, and not a fault in the page.

The originals

Every record behind this page, with a way straight to the publication or the registry entry itself. Nothing here is our text.

No record in this corpus is attributed to this approach.

The searches that were run returned nothing a declared rule could attribute to it. The sources register says what was searched and what each source permits.

Found in the sources and not yet checked

Records the sources hold about this approach that nobody has read yet. They are not evidence and are not counted anywhere on this page.

See what the sources hold — 1238 records

In detail: how all of this was measured

Nothing below has been removed or softened — it is the whole evidence model, one screen down, for anybody who wants to check the sentences above rather than take them.

Where this record was first named

The four states

Four separate statements. They are never rolled into one: a technology shown to work in rodents and never tried in people must read as exactly that.

Biologically possible

Not investigated

Nothing has been recorded either way.

Claims and their evidence states

Demonstrated in animals

Not investigated

Nothing has been recorded either way.

Claims and their evidence states

Demonstrated in humans

Not investigated

Nothing has been recorded either way.

Claims and their evidence states

Clinically available

Not investigated

Nothing has been recorded either way.

Claims and their evidence states

Combination · Prognostic value

Combination

No dataNothing has been recorded here yet. This is not a zero.

Prognostic value

No dataNothing has been recorded here yet. This is not a zero.

Readiness by injury phase and impairment band

CompleteSensory incompleteMotor incompleteMixedNot applicableAIS not reportedOutside our vocabulary
AcuteNo dataNo dataNo dataNo dataNo dataNo dataNo data
SubacuteNo dataNo dataNo dataNo dataNo dataNo dataNo data
ChronicNo dataNo dataNo dataNo dataNo dataNo dataNo data
UnknownNo dataNo dataNo dataNo dataNo dataNo dataNo data

Nothing has been recorded here yet. This is not a zero.

The eight evidence dimensions

No dataNothing has been recorded here yet. This is not a zero.

Technologies · Relationships

Nothing has been recorded here yet.

This map holds only what has been read and checked against a source, and nothing has been recorded for this section. Empty here means exactly that — not zero, and not a fault in the page.

Outcome measure

Nothing has been recorded here yet.

This map holds only what has been read and checked against a source, and nothing has been recorded for this section. Empty here means exactly that — not zero, and not a fault in the page.

Cell type, biomaterial or animal model

Nothing has been recorded here yet.

This map holds only what has been read and checked against a source, and nothing has been recorded for this section. Empty here means exactly that — not zero, and not a fault in the page.

Relationships to other technologies

No relationship to another technology has been recorded.

This map holds only what has been read and checked against a source, and nothing has been recorded for this section. Empty here means exactly that — not zero, and not a fault in the page.